45-IWay Hopper
AT Commands/S-Registers
&F0 Profile 0  Modem-like operation (default)
&F1 Profile 1  V.110 async operation
&F2 Profile 2  V.120 async operation
&F3 Profile 3  X.75 async operation
&F4 Profile 4  MLPPP async operation
Command: &Mn
Function: Asynchronous Mode
Values: n = 0 or 1
Default: &M0 (Asynchronous)
Description: Use the &Mn command to set the MTA128ST for synchronous or
asynchronous transmission. Note that synchronous transmission is not presently
supported, and this command is included for future use only.
&M0 Asynchronous mode transmission.
&M1 Synchronous mode transmissionnot presently supported.
Command: &Rn
Function: CTS Control
Values: n = 0, 1, or 2
Default: &R1 (CTS forced high)
Description: The &Rn command lets you control the state of the CTS (Clear to
Send) signal on the RS232E/V.24 interface. Normally the CTS signal follows the
state of the RTS signal when the MTA128ST is online.
&R0 CTS acts normally; that is, it follows RTS.
&R1 CTS is forced high, but still provides online flow control.
&R2 CTS is forced high, but it drops on disconnect for the period of time
set by S10. CTS still provides flow control when the MTA128ST is
online.