Resumo do Conteúdo

Página 1 - Owner’s Manual

MT56DSU2 Owner’s Manual82017502 1MultiDSU56KModel MT56DSU2Owner’s Manual

Página 2 - P/N 82017502 Rev. C

MT56DSU2 Owner’s Manual82017502 10Chapter 2 – Hardware Installation2.1 IntroductionThis chapter provides the information needed to configure and inst

Página 3 - Table of Contents

MT56DSU2 Owner’s Manual82017502 11The Mu11iDSU56K DIP switches are shown and described below.Figure 2-1 MuIttDSU56K Board Layout2.2.1 12-Position DI

Página 4 - 1.3 Description

MT56DSU2 Owner’s Manual82017502 12An adhesive-backed label containing the DIP switch setting information is provided on the bottom of theMultiDSU56K;

Página 5

MT56DSU2 Owner’s Manual82017502 13The factory default settings are indicated by an * in table 2-1.Table 2-1. MuII1DSU56K Switch SettingsSwitch

Página 6 - 1.5 Features

MT56DSU2 Owner’s Manual82017502 142.4 Installation ProcedureInstallation of the MultiDSU56K includes making cable connections to the back panel and t

Página 7 - 82017502 7

MT56DSU2 Owner’s Manual82017502 15Chapter 3 – Operation3.1 IntroductionThis chapter provides information on the operating functions of the MultiDSU56

Página 8 - 1.7 Specifications

MT56DSU2 Owner’s Manual82017502 163.2.4 Elastic StoreThis function allows the MultiDSU56K to compensate for small timing phase “drifts” that occur in

Página 9 - 82017502 9

MT56DSU2 Owner’s Manual82017502 173.2.8 RTS Forced OnWith this option enabled, the MultiDSU56K provides a continuous CTS signal, disregarding the sta

Página 10 - 2.1 Introduction

MT56DSU2 Owner’s Manual82017502 18The MultiDSU56K uses 4-wire non-loaded metallic circuits for LADS applications. The table belowoutlines approximatio

Página 11

MT56DSU2 Owner’s Manual82017502 19Chapter 4 - Troubleshooting4.1 IntroductionAll of the indicators used in normal operation of the MultiDSU56K are on

Página 12 - 82017502 12

MT56DSU2 Owner’s Manual82017502 2MultiDSU56KModel MT56DSU2Owner’s ManualP/N 82017502 Rev. CThis publication may not be reproduced, in whole or in part

Página 13 - 82017502 13

MT56DSU2 Owner’s Manual82017502 204.2.6 96 IndicatorThe 96 LED lights when the “Data Rate” selection is set at 9600 bps. This indicator will be off f

Página 14 - 2.4 Installation Procedure

MT56DSU2 Owner’s Manual82017502 214.3.1 Local Loopback TestThis test allows you to test the local DTE and the local MultiDSU56K. Use the following st

Página 15 - Chapter 3 – Operation

MT56DSU2 Owner’s Manual82017502 224.3.3 Digital Loopback Test With Test Pattern TestThis test allows you to test the local MultiDSU56K, the communica

Página 16 - 3.2.7 Clocking

MT56DSU2 Owner’s Manual82017502 234.3.5 DSU Loopback TestThis test lets you verify proper DSU operation by matching a transmitted signal to the “loop

Página 17

MT56DSU2 Owner’s Manual82017502 244.3.6 DSU Back-to-Back TestThis test lets you connect two DSUs with a back-to-back cable to verify proper DSU opera

Página 18

MT56DSU2 Owner’s Manual82017502 25Chapter 5 – Service, Warranty and Tech SupportLimited WarrantyMulti-Tech Systems, Inc. (icMTSl,) warrants that its p

Página 19 - Chapter 4 - Troubleshooting

MT56DSU2 Owner’s Manual82017502 26If you need to inquire about the status of the returned product, be prepared to provide the serial number ofthe prod

Página 20 - 82017502 20

MT56DSU2 Owner’s Manual82017502 27Appendix A - Application ExamplesINTRODUCTIONThis section illustrates several types of applications in which the Mul

Página 21 - 4.3.2 Digital Loopback Test

MT56DSU2 Owner’s Manual82017502 28DDS MULTIPOINT (POLLED) APPLICATIONSince your Central Office (CO) equipment must include “Multipoint Junction Units”

Página 22 - 4.3.4 Test Pattern Test

MT56DSU2 Owner’s Manual82017502 29LOCAL AREA DATA SET APPLICATIONIn this application, two pairs of wires provide the connection between two MultiDSU56

Página 23 - Loopback

MT56DSU2 Owner’s Manual82017502 3Table of ContentsCHAPTER 1-INTRODUCTION AND DESCRIPTION1.1 Introduction 51.2 About This Manual 51.3 Description 51.4

Página 24 - 4.3.6 DSU Back-to-Back Test

MT56DSU2 Owner’s Manual82017502 30ANALOG OFF-NET EXTENSION APPLICATIONIn this application, the MultiDSU56K is used with conventional analog modems and

Página 25 - Tech Support

MT56DSU2 Owner’s Manual82017502 31Appendix B - Interface Signals and Connector PinoutsDDS RJ48 CONNECTORPin 1Pin 8KeyAs viewed from the rearDESCRIPTIO

Página 26 - MULTI-TECH SYSTEMS, INC

MT56DSU2 Owner’s Manual82017502 32RS232C DB25S CONNECTORReceive Clock (RC) —Transmit Clock (TC) —131211109 — Test Voltage (+V)8 — Carrier Detect (CD)7

Página 27 - INTRODUCTION

MT56DSU2 Owner’s Manual82017502 33V.35 34-PIN CONNECTORCHMSWAAEEKKDJNTXBBFFLLAEKPUYCCHHMMBFLRVZDDJJNNV.35 34-PIN CONNECTORSignal Designation Signal De

Página 28

MT56DSU2 Owner’s Manual82017502 34LOOPBACK CABLE(MTS P/N 45640100)18DESCRIPTIONThis cable lets you test the MultiDSU56K when a second DSU is not avail

Página 29

MT56DSU2 Owner’s Manual82017502 35BACK-TO-BACK CABLE(MTS P/N 45050000)18DESCRIPTIONThis cable lets you test a suspect DSU by connecting it to a known

Página 30

MT56DSU2 Owner’s Manual82017502 36GlossaryThis section defines several of the terms used in this manual. For an overview of DSU basics, refer tosectio

Página 31 - As viewed from the rear

MT56DSU2 Owner’s Manual82017502 37DData Communications Equipment (DCE) — equipment that provides the function to establish, maintainand terminate a co

Página 32 - 82017502 32

MT56DSU2 Owner’s Manual82017502 38Mmaster station — see “control station”.MJU (Multipoint Junction Unit) — a digital data bridge, located at telco off

Página 33 - V.35 34-PIN CONNECTOR

MT56DSU2 Owner’s Manual82017502 39Ttest pattern — a diagnostic test for sending ,detecting and checking a pre-defined pattern of bits.two-wire circuit

Página 34 - 82017502 34

MT56DSU2 Owner’s Manual82017502 4Chapter 1 - Introduction and Description 1.1 IntroductionCongratulations! Your new MultiDSU56K is one of the finest

Página 35 - 82017502 35

MT56DSU2 Owner’s Manual82017502 5NSDOSRTSCTSSend Rcv Carrier 56K 19.2K 9600 4800 Clear Request NoSgnl Outage TestMultiDSU56KRDCDSD964819.256TMMulti-Ra

Página 36 - Glossary

MT56DSU2 Owner’s Manual82017502 61.5 FeaturesThe MultiDSU56K provides many useful features. Standard features include V.35 and RS232connections and e

Página 37

MT56DSU2 Owner’s Manual82017502 71.6 FCC Regulations for Telephone Line Interconnection1. This equipment complies with Part 68 of the FCC rules. On t

Página 38

MT56DSU2 Owner’s Manual82017502 81.7 SpecificationsModel Number MT56DSU2Device Operation combined DSU and CSUData Rates Synchronous: 2400, 4800, 960

Página 39 - Contrast ‘Iour-wire circuit”

MT56DSU2 Owner’s Manual82017502 9Delay Times (in secs.):RTS/CTSDCD on DCD off2400 8.1 7.5 7.0 4800 4.3 2.6 3.5 9600 2.2 1.6 1.5 19200 1.0 0.8 0.7 5600