CHAPTER 3 SPECIFICATIONS
SocketModem EV-DO MTSMC-EV3 Device Guide
14
Radio
Protocol
Instant Peak TX
Current (Amps)
Total Inrush Charge
measured in Coulombs
Inrush Duration (Total
Inrush charge duration
during powerup).
3.3 Volts
US Cellular
0.920
18.23mC
1.91ms
PCS
0.936
18.23mC
1.91ms
EV-DO
0.768
18.23mC
1.91ms
5 Volts
US Cellular
0.604
17.90mC
1.82ms
PCS
0.624
17.90mC
1.82ms
EV-DO
0.508
17.90mC
1.82ms
Notes:
AT+CFUN=1 used to set radio function and power mode.
Instant Peak Tx: The peak current during a transmission burst period or connection. This current is handled by
bulk capacitance in a design.
Measured Current: The continuous current during a Transmit with the radio transmitter at specified power.
Inrush Charge: The total inrush charge current amplitude at power on.
MTSMC-EV3-MI-IP
Radio
Protocol
AT command
used to set
radio function
and power mode
Connection
No Data
(Amps)
Half Power
Max Power
Average Measured
Current (Amps)
Average Measured
Current (Amps)
3.3 Volts
US Cellular
AT+CFUN=1
0.140
0.302
0.890
PCS
AT+CFUN=1
N/A
0.285
1.041
EV-DO
AT+CFUN=1
0.124
0.304
0.818
5 Volts
US Cellular
AT+CFUN=1
0.090
0.190
0.580
PCS
AT+CFUN=1
N/A
0.180
0.616
EV-DO
AT+CFUN=1
0.083
0.187
0.485
Note: This data is measured using an Agilent call box connected to the cellular radio.