Multitech MTCBA-C-IP-N1 Especificações Página 229

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 253
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 228
Chapter 18 – Hardware-Related Commands
Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 229
Unsolicited Result Codes:
URC 1
URCs will be automatically sent to the TA when the temperature reaches or exceeds the critical level or when it
is back to normal.
URC 2
^SCTM_B: <m>
for module (board) temperature
Examples:
Example 1
URCs issued when the operating temperature is out of range:
^SCTM_B: 1 Caution: Engine close to overtemperature limit.
^SCTM_B: 2 Alert: Engine is above overtemperature limit and switches off.
^SCTM_B: -1 Caution: Engine close to undertemperature limit.
^SCTM_B: -2 Alert: Engine is below undertemperature limit and switches off.
Example 2
URCs issued when the temperature is back to normal (URC is output once):
^SCTM_B: 0 Engine back to normal temperature.
Vista de página 228
1 2 ... 224 225 226 227 228 229 230 231 232 233 234 ... 252 253

Comentários a estes Manuais

Sem comentários